PowerModularCoolingEPCSpeed to PowerCompanyTalk to an engineer
AxisOne all-prefabricated modular data hall
AxisOneAll-Prefabricated Modular AI Data Centers

AI capacity,
delivered on schedule.

AxisOne designs, manufactures and delivers prefabricated modular AI data centers, with our own liquid cooling and power equipment inside, built turnkey as your EPC partner.

30–34 MWIT capacity per reference campus
144–227 kWPer liquid-cooled rack
8–12 wksOn-site installation
0+Engineers & specialists

01  /  The Challenge

The bottleneck moved from chips to buildings.

GPUs ship in weeks. The infrastructure to house, cool and power them takes far longer. Every month a cluster waits on a building is revenue that never comes back.

A  /  SUPPLY

Long-lead equipment sets the schedule

Switchgear, cooling plant and power equipment are back-ordered across the industry. Projects wait in line for parts instead of building.

B  /  INTERFACES

Too many vendors, too many interfaces

A typical build stitches together a dozen suppliers and contractors. Every interface is a place where scope, schedule and warranty slip.

C  /  DENSITY

AI racks outgrew legacy design

Liquid-cooled AI racks now run well past 100 kW. Facilities designed for enterprise IT cannot carry that heat or that electrical load.

AxisOne closes the gap with three self-developed foundations, power, cooling and control, built in our own factories and delivered turnkey.

How an AI campus comes together

02  /  Power

Start with megawatts.

Power decides where and how fast a campus gets built. AxisOne delivers every step from onsite generation and medium voltage down to the rack, factory integrated and tested.

Jereh energy equipment
Onsite generation

Behind-the-Meter Power

  • Onsite natural gas generation from the Jereh Group energy portfolio
  • Bridge or prime power while the grid catches up
Medium-voltage power module
Medium voltage

MV Power Module

  • Factory-integrated MV switchgear in a 20 ft module
  • Multi-source automatic transfer with electrical interlock
Low-voltage AC power module
Low voltage

LV AC Power Modules

  • IT power module: 3 MW nominal
  • Utility power module: 2 to 3 MW nominal
  • Factory-integrated in 53 ft modules
Switchboard
Distribution

Switchboard

Main busbar
5,000 A max rated
SCCR
100 kA
Lithium-ion battery module
Backup

Lithium-ion Battery Module

  • Up to 400 kWh per 20 ft module
  • High-rate discharge for IT backup
Integrated power equipment hall
Integration

Power · Cooling · Control

  • Self-developed foundations designed to work as one system
  • No vendor lock-in on core controls

03  /  Modular Campus

All-prefabricated.
Plug-and-play.

Modular design, factory prefabrication, integrated assembly and pre-testing. Every module arrives wired, piped and tested, ready to set and connect.

Reference campus layoutAxisOne all-prefabricated modular AI data center campus layout

Modular AI Data Center

Build AI capacity with confidence.

30–34MWIT capacity
312Racks
144–227kWPer liquid-cooled rack
Tier III+Target availability
Lower PUE / WUEDense GPUs & liquid coolingStandardized, scalable installWaterproof roof

The module family

Seven standard modules combine into a complete campus. Each is configurable to your site and scale.

IT module
8 × 40 ft

IT Module

  • 2 rack columns, 3 MW rated capacity
  • 4 power paths, factory wired
  • Liquid piping, factory prefabricated
Cooling distribution module
8 × 20 ft

Cooling Distribution Module

  • Uniform cooling to IT racks
  • Prefabricated, rapid site hookup
  • 2.5 to 3 MW cooling range
Cooling source pumping module
1 × 45 ft

Cooling Source Pumping Module

  • Integrated cooling pumping equipment
  • 100% prefabricated, site hookup
  • 4.5 to 6 MW cooling range
Lithium-ion battery module
1 × 20 ft

Lithium-ion Battery Module

  • Backup power module
  • High-rate discharge
  • Capacity up to 400 kWh
Low-voltage AC power module, IT
1 × 53 ft

LV AC Power Module (IT)

  • Factory-integrated power assembly
  • 3 MW nominal capacity
Low-voltage AC power module, utility
1 × 53 ft

LV AC Power Module (Utility)

  • Factory-integrated power assembly
  • 2 to 3 MW nominal capacity
Medium-voltage power module
1 × 20 ft

Medium-Voltage Power Module

  • Factory-integrated MV switchgear
  • Multi-source auto transfer with electrical interlock
Configurable

Sized to your site, load and density.

  • Phased scale-out
  • Re-deployable modular assets
  • Factory-tuned before shipment
Request a layout

04  /  Liquid Cooling

Cooling control, close to the load.

A complete liquid-cooling matrix covering the full AI data center loop, from the cold plate to heat rejection, for precise thermal management of high-density racks.

AxisOne 1.25 MW sidecar coolant distribution unitBuilt for North America

Featured product

1.25 MW Sidecar CDU

A liquid-to-liquid coolant distribution unit that separates facility water from the IT loop, holds coolant conditions steady and gives operators continuous monitoring and alarms.

Cooling capacity1.25 MW / 355.4 TR
Secondary flow317 gpm
Temperature control±0.9 °F
Rack density50–200 kW per rack
CoolantWater (EG or PG compatible)
Heat capture≥95%
Electrical480 V / 3 PH / 60 Hz
Dimensions (W×D×H)35.4 × 49.2 × 90.6 in
Multi-unit parallel15–25% headroom for next-gen hardwareGPU cold-plate compatible
Plate heat exchanger
FeatureHeat exchange and circulation
CDU control screen
AdvantageSeparate facility and IT fluids
CDU pumps and filtration
BenefitManage the IT cooling loop
Two fluid loops. One thermal interface.1.25 MW Sidecar CDU operating point
Facility loop
Supply96.8 °F
Return123.8 °F
CDUHeat exchanger
IT loop · rack manifolds + cold plates
Supply104 °F
Return131 °F

The cooling matrix

Distribution and heat rejection, engineered to work together. All units run on 480 V / 3 PH / 60 Hz with water, EG or PG coolant.

CDU 2.2 MW
Distribution

CDU 2.2 MW

Flow
793 gpm
Control
±0.9 °F
Size
78.7 × 55.1 × 94.5 in
Magnetic-bearing air-cooled chiller
Heat rejection

Air-Cooled Chiller, Magnetic Bearing

  • 14.2 to 426 RT (50 to 1,500 kW), modular
  • LWT / EWT 95 / 113 °F
  • Dual feeds, N+1, 180 s recovery
  • Tower-free, low-GWP cooling
Dry cooler 1.55 MW
Heat rejection

Dry Cooler 1.55 MW

Flow
634 gpm
Control
±1.8 °F
Size
528 × 104 × 89 in
Dry cooler 5.0 MW
Heat rejection

Dry Cooler 5.0 MW

Flow
1,920 gpm
Control
±1.8 °F
Size
732 × 186 × 144 in

05  /  Turnkey EPC

One contract. One schedule. One team accountable.

Beyond our own equipment, AxisOne's professional engineers deliver the campus end to end: design, prefab, test, ship, install and commission.

E

Engineer

In-house R&D, design, structural and MEP teams, managed as one.

  • Design + structure + MEP + controls
  • U.S. PE-sealed engineering
  • AHJ-ready design
P

Procure & Prefabricate

Self-developed equipment, centrally procured and fabricated in-house.

  • Modular MEP, multi-module assembly
  • Factory inspection, aging and testing
  • Marine-grade protection and logistics
C

Construct & Commission

On-site execution by the same team that designed and built the modules.

  • Set, reconnect, energize and test
  • Start-up and commissioning
  • Clear path to final acceptance
01Design

Site-specific layout from standard modules

02Prefab

Fabricated and assembled in our factories

03Test

Factory inspection, aging and testing

04Ship

Flat-rack and oversize routing, customs, protection

05Install

Receive, hoist, reconnect

06Commission

Energize, test, start up

ULUL certified equipment
AHJAHJ-ready design and execution
PEU.S. PE-sealed engineering
AxisOne electrical room inside a modular data center

Why a single EPC matters

The interfaces are where projects fail. We own them.

Self-developed, centrally procured, in-house fabricated and on-site executed. Prefabrication plus turnkey EPC means faster delivery, fewer surprises and a lower total cost of ownership.

Typical approachSeparate designer, a dozen OEMs, a GC and a commissioning agent
AxisOneOne partner from design through energization and service

06  /  Speed to Power

Build in parallel.
Energize sooner.

Modules are built and tested in our factories while your site is prepared. Once they arrive, on-site installation takes 8 to 12 weeks.

Project delivery schedule
DesignProcure & waitFactory buildSite & commission
Stick-builtSequential, multi-vendor
Design
Procurement & long-lead wait
Site construction & commissioning
AxisOnePrefab + turnkey EPC
Design
Factory prefab & test
Site prep → 8–12 wk install → commission
Illustrative schedule. Actual timing depends on site, scope and permitting.Months →

Our factories, our queue

We build our own modules, cooling and power equipment, so your schedule is not hostage to someone else's backlog.

Tested before it ships

Modules are pre-integrated and tested in the factory. Problems get solved on our floor, not on your site.

8 to 12 weeks on site

Plug-and-play modules mean less field labor, fewer trades and a short path from delivery to commissioning.

07  /  The Company Behind It

0+

people behind every AxisOne project.

Jereh AxisOne is backed by Jereh Group, a global energy equipment manufacturer with more than 9,000 employees across engineering, R&D, manufacturing and field service. That depth is why we can commit to schedules others cannot.

In-house fabrication

Modules, cooling and power equipment built in our own manufacturing bases.

Engineering & R&D

Design, structural, MEP and controls teams, backed by one-stop management.

Energy heritage

Decades of building heavy energy equipment for demanding operators worldwide.

U.S. presence

U.S. office in Sunnyvale, California, and operations in Houston, Texas.

Jereh facility in Houston, TexasHouston, Texas

Global footprint

Manufacturing bases and delivered projects

A global production and delivery network with a home base in Houston.

HoustonTexas, USA
DubaiUAE
YantaiChina
ZhongshanChina

08  /  In the Field

Engineered. Built. Running.

From the switchgear room to the cooling plant, every system on site is designed and built by the same team.

09  /  Our Core Advantages

Why AxisOne.

Hyperscalers, neoclouds and developers choose AxisOne when the date matters as much as the design.

01

Purpose-designed for AI

Built for high-density HPC clusters and liquid cooling from the start.

02

Standardized and customizable

Factory-tuned modules, configured to your site and scale.

03

Rapid deployment

Factory pre-integrated and tested, then 8 to 12 weeks on site.

04

Scalable and redeployable

Phased scale-out with modular assets that can move when you do.

05

Cost advantage

Lower CAPEX and OPEX for a lower full-life cost.

06

Self-developed equipment

Secure core controls and our own power and cooling products, with no vendor lock-in.

10  /  Start a Project

Tell us your megawatts and your date.

Share your site, load and target energization date. An AxisOne engineer will come back with a modular layout, a delivery path and a schedule you can plan around.

Emailaidc@axisoneai.com
U.S. Office1241 Alderwood Avenue, Sunnyvale, CA 94089